Mounting cutouts panel mounting – Rockwell Automation 6182 Industrial Computer for the Windows CE Operating System User Manual

Page 25

Advertising
background image

Installation

2–5

Publication 6182-UM001D-EN-P

The following figure provides the dimensions for making the panel or
enclosure cutout for the RAC6182 Industrial Computer.

Table C
Mounting Cutout Sizes

Display Size

Height

Width

7.7 in. version with keypad

197.8 [7.79]

295.8 [11.65]

12.1 in. version with touchscreen

256.8 [10.11]

337.6 [13.29]

12.1 in. version with keypad

256.8 [10.11]

389.9 [15.35]


To install the RAC6182 Industrial Computer in a panel:

ATTENTION: Disconnect all electrical power from the
panel before making cutout.

Make sure the area around the panel cutout is clear.

Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.

Failure to follow these warnings may result in personal
injury or damage to the panel components.

To install the RAC6182 Industrial Computer in a panel:

1. Cut an opening in the panel using the panel cutout dimensions

provided on Page 2-5.

2. Make sure the RAC6182 Industrial Computer sealing gasket is

properly positioned on the terminal. This gasket forms a
compression type seal. Do not use sealing compounds.

3. Place the RAC6182 Industrial Computer in the panel cutout.

Mounting Cutouts