3–6

Connecting External Devices

Publication 6182-UM001D-EN-P

The RAC6182 Computer has two serial ports – COM1 and COM2, both
with DB9 male connectors.

The COM1 port supports RS232, RS422, and RS485 physical signals.
The COM1 physical signals are software-selectable.

The COM2 port supports only RS232 physical signals. The COM2 port
is used to connect to a host PC using ActiveSync.

Note:

You must use a null modem cable (6189-2NMCBL) to
connect the COM2 port to a host PC. For information on
the null modem cable, refer to Appendix D, RAC6182
Point-to-Point Communications.

Note:

For information on connecting the RAC6182 Industrial
Computer to a host PC using the serial port, refer to
Chapter 14, Communications Configuration.

Table G
DB9 Male Connector Pin-Out

PIN

RS232 Signal

(COM1 and COM2)

RS422/RS485 Signal

(COM1 Only)

1

DCD TXD(+)

2

RXD TXD(-)

3

TXD RXD(+)

4

DTR RXD(-)

5

SGND SGND

6

DSR DH485

TXENBL

7

RTS Not

connected

8

CTS Not

connected

9

RI Not

connected