Power connections – Rockwell Automation 6182 Industrial Computer for the Windows CE Operating System User Manual

Page 27

Advertising
background image

Installation

2–7

Publication 6182-UM001D-EN-P

A three-contact removable terminal block is used to connect power to the
RAC6182 Industrial Computer. The RAC6182 Industrial Computer AC
version accepts 120/240V AC. The AC power supply is autoranging.
The DC version accepts 18-32V DC. The removable terminal blocks
are different on the AC and DC versions and cannot be interchanged.

ATTENTION: The power supply must be connected to
an earth ground. Failure to follow this warning could
result in severe electrical shock.

ATTENTION: Some 1784 communication cards have a
connector like the one used for the RAC6182 power
connector. Do not plug power into connectors on these
cards.

The terminal block is equipped with two retainer screws to prevent
accidental interruption of power to the RAC6182 Industrial Computer.
Tighten the screws on the AC version to a torque of 5 in–lbs (0.56 N•m).
Tighten the screws on the DC version to a torque of 2.5 in–lbs (0.28
N•m).

WARNING: EXPLOSION HAZARD! Do not connect
or disconnect equipment unless power has been switched
off or the area is known to be non-hazardous.

Power Connections

Advertising