Chapter 2
Configuring the RediPANEL Module

2–5

Figure 2.2
DIP Switch Bank 1
Rack Address Settings for PLC-3, PLC-5 and SLC Processors

I/O Rack

Address

Switch Settings

I/O Rack

Switch Settings

I/O Rack

Address

1

2

3

4

5

6

I/O Rack

Address

1

2

3

4

5

6

00 ➀

on

on

on

on

on

on

40

off

on

on

on

on

on

01

on

on

on

on

on

off

41

off

on

on

on

on

off

02

on

on

on

on

off

on

42

off

on

on

on

off

on

03

on

on

on

on

off

off

43

off

on

on

on

off

off

04

on

on

on

off

on

on

44

off

on

on

off

on

on

05

on

on

on

off

on

off

45

off

on

on

off

on

off

06

on

on

on

off

off

on

46

off

on

on

off

off

on

07

on

on

on

off

off

off

47

off

on

on

off

off

off

10

on

on

off

on

on

on

50

off

on

off

on

on

on

11

on

on

off

on

on

off

51

off

on

off

on

on

off

12

on

on

off

on

off

on

52

off

on

off

on

off

on

13

on

on

off

on

off

off

53

off

on

off

on

off

off

14

on

on

off

off

on

on

54

off

on

off

off

on

on

15

on

on

off

off

on

off

55

off

on

off

off

on

off

16

on

on

off

off

off

on

56

off

on

off

off

off

on

17

on

on

off

off

off

off

57

off

on

off

off

off

off

20

on

off

on

on

on

on

60

off

off

on

on

on

on

21

on

off

on

on

on

off

61

off

off

on

on

on

off

22

on

off

on

on

off

on

62

off

off

on

on

off

on

23

on

off

on

on

off

off

63

off

off

on

on

off

off

24

on

off

on

off

on

on

64

off

off

on

off

on

on

25

on

off

on

off

on

off

65

off

off

on

off

on

off

26

on

off

on

off

off

on

66

off

off

on

off

off

on

27

on

off

on

off

off

off

67

off

off

on

off

off

off

30

on

off

off

on

on

on

70

off

off

off

on

on

on

31

on

off

off

on

on

off

71

off

off

off

on

on

off

32

on

off

off

on

off

on

72

off

off

off

on

off

on

33

on

off

off

on

off

off

73

off

off

off

on

off

off

34

on

off

off

off

on

on

74

off

off

off

off

on

on

35

on

off

off

off

on

off

75

off

off

off

off

on

off

36

on

off

off

off

off

on

76

off

off

off

off

off

on

37

on

off

off

off

off

off

➀ Rack 00 not valid with PLC-5s.

Specifying First I/O Group

First I/O

roup

Switch Settings

First I/O

Group

7

8

0

on

on

2

on

off

4

off

on

6

off

off

Advertising