3–8
Mounting tabs are built into the Module. After sliding the Module into the
enclosure, the tabs secure the Module until the mounting brackets are in
place. The installation procedure follows.
Mounting Tabs and Brackets
Mounting
Tabs
To install the 800A and Sealed Membrane Modules:
1. Cut an opening in the panel approximately 5.86 inch (148.84mm) H x
8.61 inch (218.69mm) W. See Figure 3.1.
Figure 3.1
Panel Cutout Dimensions in Inches (mm)
800A and Sealed Modules
8.61
(218.69)
Panel Cutout
5.86 x 8.61
(148.84 x 218.69)
3.69
(93.73)
6.375
(161.93)
5.86
(148.84)
0.62
(15.75)
1.06
(26.92)
7.375
(187.33)
9.25
(234.95)
➀
➀ These 2 additional 0.312 inch (7.92 mm) diameter holes are required for NEMA Type 4X
push button modules.
7.00
(177.8)
3.12 (79.25) Dia.
4 Places
0.26
(6.60)
Installing the 800A and
Sealed Membrane Modules