Rockwell Automation 2705 RediPanel Push Button Module User Manual

Page 57

Advertising
background image

Chapter 4
Programming the RediPANEL Modules

4–18

Figure 4.7 shows the instruction addresses for the RediPANEL Module
configuration in Figure 4.6 The first 8 words of files N11 and N12 are
reserved for the Sub I/O Scanner utility functions.

Figure 4.7
PLC-5/15 and Sub I/O Scanner Ladder Logic Example

Output Addresses

N12:00/00 - N12:07/15

Reserved for Sub-Scanner Utility Functions.

N12:08/00 - N12:09/15

Reserved for lamp addresses for Module 1
configured for rack 1 module group 0 and 1

N12:10/00 - N12:11/15

Reserved for lamp addresses for Module 2
configured for rack 1 module group 2 and 3

N12:12/00 - N12:13/15

Reserved for lamp addresses for Module 3
configured for rack 1 module group 4 and 5

14

14

Module 3

Push Button #15

N11:12

Module 3

Lamp #15

N12:12

15

15

Module 1

Push Button #16

N11:08

Module 1

Lamp #16

N12:08

RediPANEL

Address Profile

Input Addresses

N11:00/00 - N11:07/15

Reserved for Sub-Scanner Utility Functions

N11:08/00 - N11:09/15

Reserved for button addresses for Module 1
configured for rack 1, module group 0 and 1

N11:10/00 - N11:11/15

Reserved for button addresses for Module 2
configured for rack 1 module group 2 and 3

N11:12/00 - N11:13/15

Reserved for button addresses for Module 3
configured for rack 1 module group 4 and 5