Appendix G
Installing/Replacing Push Buttons

G–4

To install or replace 800EP/EM Push Buttons:

1. Without removing the wiring from the contact block, remove the latch

with a screw driver.

2. Remove the locking ring on the back of the operator.

3. Remove the operator by pulling it out from the front of the panel.

4. Install the new operator by inserting it into the panel from the front and

attaching the locking ring. Torque EP (plastic) mounting ring with drive
wrench 800E-AW2 to 15 lb-in. Torque EM (metal) mounting ring with 24
mm socket to 40 lb-in.

5. Snap the latch back onto the operator.

Typical Connection Diagram

DIP Switches

Plug blue wires
into terminal X1 (+)

Plug blue wires
into terminal 3

Plug blue wire
into terminal 4

Plug yellow wire
into terminal X2 (–)

Blue wire from bundle

Blue wire back to bundle.
Note: This wire does not
exist on the end of the
blue wire strand

Installing/Replacing
800EP/EM Push Buttons