Rockwell Automation 2705 RediPanel Push Button Module User Manual
Page 87

LED Upgrade Kit
Appendix C
800A Switch Replacement Kit
C–4
10. A replacement device can be inserted from the front. Note: Make sure
new switch is lined up in template before securing the retaining ring.
11. Place faceplate and template face down on a flat surface. Replace the
retaining ring and torque to 12 in-lbs.
Note: Examine for bent pins and check for alignment problems.
12. Starting at one of the corners, carefully align PC board sockets over
pins. Check at eye level to verify that pins and sockets line up. Make
the appropriate adjustments if necessary.
13. Carefully apply downward pressure to fully insert pins in sockets.
14. Examine pins to make sure all are fully inserted into the sockets.
15. Replace the four screws that secure the PC board to the push buttons.
Torque to 9 in-lbs.
16. Plug in the ribbon cables and reconnect wiring. Make sure all
connections are seated properly.
17. Slide the push button assembly into the sheet metal housing.
18. Replace the 4 screws that secure the faceplate to the housing. Torque
to 18 in-lbs.
To Verify Operation of Modified Push Button Module:
Apply power and proceed through the Push-to-Test sequence. See Chapter 5.