Appendix G
Installing/Replacing Push Buttons

G–3

To attach the 800T Adaptor Kit to an 800T/H Push Buttons:

1. Remove the wiring screws from the contact block and transformer on the

800T/H push button.

2. Insert circuit board posts into the appropriate wiring screw holes on

the push button contact block and transformer.

3. Put spacers in position and line-up caps on circuit board with

circuit board posts.

4. Press circuit board down so it is firmly seated on circuit board posts.

5. Secure the circuit board to the push button with enclosed screws.

Attaching the 800T Adapter Kit to an 800T/H Push Button

Circuit Board

Spacers

Push Button

Attaching the 800T Adaptor
Kit to 800T/H Push Buttons.