The ladder diagram in Figure 4.10 shows how to flash a lamp with a button.
The program uses Rack 2, group 0 and bit location 0 (Push Button #1) with
Lamp #6 for the output.
For applications in which a RediPANEL Module communicates via a scanner
module this is the only programming that is necessary.
Figure 4.10
Flashing a Button Lamp
When button #1 (I:20/00) is pressed, turn on lamp for button #6 (O:20/05).
I:20
]
[
00
When button #2 (I:20/01) is pressed along with push button #1, flash lamp #6 (O:21/05).
I:20
]
[
01
O:20
(
)
05
O:21
(
)
05