Appendix B
Custom RediPANEL Modules

B–3

(2705-E3) must be installed from the second contact block to the first contact
block terminal screw. If the adjacent position contains a pilot lamp, the
existing wires stay as is in the adjacent position. The lamp wires and adjacent
contact block wires not used must be insulated to protect them from touching
any other conductive material. The wire terminal should be insulated with
heat shrink tubing or tape and secured to the cable assembly with a tie wrap.

When the switch is actuated left, the normal input image table bit will be set.
When the switch is actuated right, the adjacent location that was used will be
set. If the normal output image table bit is set, the selector switch lamp will
illuminate. If the adjacent output image table bit is set, the adjacent pilot
lamp will illuminate.

Pilot Lamp Only

A pilot lamp only may be installed in any position. The blue and yellow
wires from the cable assembly will connect to the lamp terminals in the
normal fashion.

The switch terminals wires (blue and grey) are not used and must be
insulated to protect them from touching any other conductive material. The
wire terminal should be insulated with heat shrink tubing or tape and secured
to the cable assembly with a tie wrap.