4.45. I/O Complex Equipment ‘DX7488’

Description:

T7484 Monitored Guarded Digital Output Module, 120V dc. The Monitored Guarded
Output Module provides switching of 90V ac to 130V dc power to 16 field outputs. The
outputs are arranged in two groups of 8 outputs, where each group is powered from a
common power source. This board definition is for a dual module configuration. Each
module can be in any Regent rack or slot. All data attached to this definition is
unpacked with BOOLEAN variables used.

OEM PARAMETERS

OEM parameter

Valid numbers

Description

TICS_CHASSIS
TICS_SLOT

1 – 10
1 – 8 (Chassis 1)
1 – 12 (Expander
Chassis)

The TICS chassis & slot number where the TMR Interface
module is placed

REGENT_CHASSIS
REGENT_SLOT

1 – 16
1 – 10

The chassis & slot number within the Regent+Plus I/O
where the first Module is placed.

PARTNER_CHASSIS
PARTNER_SLOT

1 – 16
1 – 10

The chassis & slot number within the Regent+Plus I/O
where the second Module is placed

MONITER_MASK

1 = mask fault LEDs
0 = enable fault LEDs

First module fault LED mask. Entered as a 16 bit word. Bit
0 will mask channel 1,bit 15 will mask channel 16. This field
will mask the implementation of the fault LEDs on the
module. Input status is not affected.

FREQUENCY

0 – 1

Frequency of the module.
0 - 60Hz, 1 – 50Hz.

CONFIGURATION

PHYSICAL MODULE:

RACK 1:

16 BOOLEAN outputs

States to be written to the two modules identified by the OEM parameters.
Channel 1 is module channel 1 and Channel 16 is module channel 16.
TRUE - channel high FALSE - channel low

RACK 2:

16 BOOLEAN inputs

Inputs reflecting the channel status of the first module of the two modules
specified.
Channel 1 is the state of module channel 1, Channel 16 is the state of
module channel 16.
FALSE - channel ok, TRUE - channel fault

RACK 3:

16 BOOLEAN inputs

Inputs reflecting the channel status of the second module of the two
modules specified.
Channel 1 is the state of module channel 1, Channel 16 is the state of
module channel 16.
FALSE - channel ok, TRUE - channel fault

RACK 4:

2 BOOLEAN inputs

Inputs reflecting the board of the two modules specified.
Channel 1 is he state of the first module, Channel 2 is the state of the
second.
FALSE – board ok, TRUE - board fault

Notes:

1. All parameters must be supplied, even for virtual boards.

2. Trusted

TM

chassis and slot numbers start at 1, Regent+Plus I/O chassis and slot numbers

start at 1.

EXTRA INFORMATION

Writing to a channel of board 1 will cause physical writes to be made to both boards as identified by the
parameters associated with the board. Both boards must be managed by the same TMR Interface.