Group 8 - shield gas proportional valve (v1) – Tweco 400 Ultra-Cut(May 2014) User Manual

Page 100

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

4-28

OPERATION Manual 0-5302

7-6

Outlet pressure high

Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve; defective

pressure sensor (PS6); DPC Control PCB

Group 8 - Shield Gas Proportional Valve (V1)

8-1

Valve open

Check for open connection; Replace valve.

8-2

DPC inlet Supply pressure

low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.

8-3

Outlet pressure too low

Valve full open but pressure still too low. Leak in plasma hose to torch; defective control valve;

defective pressure sensor (PS5); DPC Control PCB

8-4

Outlet pressure low

Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure sensor

(PS5); DPC Control PCB

8-5

Outlet pressure Too high

Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch, DPC mani-

fold; defective control valve; defective pressure sensor (PS5); DPC Control PCB

8-6

Outlet pressure high

Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve; defective

pressure sensor (PS5); DPC Control PCB

Group 9 - Shield H2O Proportional Valve (V2)

9-1

Valve open

Check for open connection; Replace valve.

9-2

DPC inlet Supply pressure

low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.

9-3

Outlet flow too low

Valve full on but pressure still too low. Leak in shield hose to torch; Defective control valve (V2);

Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

9-4

Outlet flow low

Tracking error, outlet pressure too low. Leak in shield hose to torc; Defective control valve (V2).

Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

9-5

Outlet flow Too high

Valve set to minimum but valve outlet pressure still too high. Mineral build up or other restriction in

control valve (V2), DPC manifold, shield hose or torch; Defective control valve (V2)/ Defective pres-

sure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

9-6

Outlet flow high

Tracking error, outlet pressure too high. Mineral build up or other restriction in control valve (V2),

DPC manufold, shield hose or torch; Defective control valve (V2); Defective pressure sensor (PS5)

or flow sensor (FS-1) if equiped; DPC Control PCB

Advertising
This manual is related to the following products: