Tweco 400 Ultra-Cut(May 2014) User Manual

Page 86

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

4-14

OPERATION Manual 0-5302

You can change consumables by removing power or using the “Plasma Disable” SW.

If you remove power the system does not remember what gasses were last used so you have to select the process again and

it will do a complete purge including nitrogen buffer even if you do not change gas types.

With “Plasma Disable” the system remembers what was used last and does only the amount of purge necessary possibly

saving time.

11. Use “Plasma Disable”.

a) You may use the Plasma Disable when removing the torch cartridge to change or inspect consumables. Plasma

disable stops coolant pump, shuts off all gas solenoids, removes power from the inverter (power supply) and pilot

circuits, inhibits the arc starter ignition (HF) circuit. It does not remove power from the TSC 3000 or the systems

logic and communications circuits so you do not need to go through as long a power up process after replacing the

consumables.

b) If changing to a process with a different gas type you may want to select it before enabling the plasma otherwise it

will start purging the old process and when you do select the new one it will purge again taking more time.

c) If you are not changing gas type you may want to turn on the Enable first to start the purge while you enter the

process.

12. Shutting off power.

a) If you chose to shut off power for inspecting or changing consumables, or any other purpose, the system does not

remember what you were doing last so you will have to go through the complete sequence from the beginning starting

with step 1.

Operational Suggestions

1. Wait four minutes before setting the ON/OFF switch to OFF after operation. This allows the cooling fans to remove

operating heat from the power supply.

2. For maximum parts life, do not operate the pilot arc any longer than necessary.

3. Use care in handling torch leads and protect them from damage.

4. When using water as the shield note the following:

• Use clean drinking quality tap water to help prevent particulate build-up within the system water shield plumbing.

• Particulate contamination and build-up can cause reduced consumable parts life and premature torch failure.

• A cartridge type particulate water filter may help achieve optimum cutting performance.

Advertising