ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-40

INSTALLATION Manual 0-5302

2. Reinstall the Arc Starter Cover. Ensure that the ground wire is not crimped between the cover and the base.

Art # A-12059

Lower screws

(2 per side)

Upper screws (2 per side)

Cover

Ground Wire

3. The Arc Starter must be grounded; the grounding terminal is marked . Refer to the previous section for grounding

details.

Ground Cable

Art # A-04758

1 Nut and 1 Washer