NOTE

There are holes added in the rear panel for customer wiring. This, rather than the one in the CCM will be the preferred

place for customer added wiring (and strain relief) for connections to height controls, etc..

3.17 HE400 COOLER

Used in series with the existing cooling system of the Ultra-Cut XT™ series power supplies, the HE400 Cooler provides neces-

sary additional water cooling for the torch head when cutting at over 300amps. The HE400 fan is thermally controlled to operate

whenever the Ultra-Cut fan and pump is on and the coolant temperature is above a predetermined level. It may come on anytime

while the main pump is operating.

!

WARNING

Do not disassemble the Cooler with the power applied or the coolant flowing. Dangerous 220 AC voltages and high

pressure liquid are present.

Locate the Cooler so that there is adequate ventilation in front of and behind the unit and do not place or stack anything on top

of the unit.

2’ (0.6 m)

2’ (0.6 m)

3”

76 mm

3”

76 mm

Art # A-09623

NOTE

Ensure the four coolant lines described below are connected and leak free before connecting power to J71.