INV FLT (D1, INV FLT LED, red, on the Inverter Control and Fault board)

Several things can cause Inv Flt (Inverter Fault). Inverter fault is indicated by an LED, D1 on the Inverter Control and Fault

board. Inverter Fault, when it occurs, is latched on. The latch is reset next time the inverter is enabled unless it is still active

in which case it is immediately latched again. Inverter Fault will set the codes 247-252 unless it’s in conjunction with another

fault in which case that fault code may be set.

Things that can set the inverter fault:

• The local (to the inverter) + 12V & -12V bias supplies out of tolerance. There are LEDs on the Cap/Bias board that

light indicating these bias supplies are present but don’t verify they are in tolerance. It’s not likely this would happen.

More likely that fault related to the +/-12V the supply would be missing and it’s LED not on.

• Capacitor imbalance. In a cap imbalance condition D3, red Led on the main board (lower left corner of bottom or “A”

section and upper left corner of the upper or “B” section), will latch on.

• Primary over current. This is an over current condition in main switching transformer’s primary. This will latch on

but is cleared when the inverter is enabled unless it is still active in which case it is immediately latched again.

• Inverter over temperature sets the Fault signal and LED but has its own fault signal to the CCM. See OT Flt below.

OT FLT (D14, OT FLT, Inverter Control and Fault board)

• Inverter over temperature lights LED D14 on the Inverter Control and Fault board and will latch the fault signal and it’s

LED but also has its own separate fault so that will be reported as a code in the range of 253-258 or 259-264.

PWR Present

• When power is first applied to the inverter (contactor closed) CCM checks for presence of the +12V bias on the Inverter

Control and Fault board. If not present will set codes in the range of 265-270.

IS_ID (A, B, or C)

VAC_SEL (A or B)

201

Missing AC Phase

The System Bias Supply board contains circuits to detect if one of the 3 AC input phases is missing. Along with that it can

also detect if the AC voltage is too low or too high. Three phase voltage is supplied from the input terminals through the ON/

OFF Switch / circuit breaker CB1 to the System Bias board. The System Bias can operate on any 2 of the 3 phases to supply

control power and fault detection.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J62

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J27

GND

+V

1

2

4

3

HCPL-817

U?

Missing Phase a

Missing Phase b

GND

To CPU PCB

J29-16

Missing Phase

I/O PCB

SYSTEM BIAS PCB

CB1

ON / OFF

F2

F1

J60-9,18

J60-5,14
J60-1,10

3 phase AC

Art # 12310

Normally when the phase is not missing the transistor is on which turns on the opto-isolator making the signal “Missing

Phase” low.

Causes for 201, missing phase code. Codes are displayed two different ways, with an “L” meaning “Latched” or “Last”, before

the number meaning it was a problem but isn’t right now or with an “E” meaning the problem exists now.

L201 :

Most likely cause is an intermittent problem with the incoming power or possibly a loose connection on the power cord at

the back or the Ultra-Cut or Auto-Cut plasma supply.