Group 3 - Inlet Pressure Faults

3-1

Plasma Gas High (>145 PSI)

Reduce pressure from gas supply; defective pressure sensor (PS4).

3-2

Pilot Gas High (>145 PSI)

Reduce pressure from gas supply; defective pressure sensor (PS3).

3-3

Shield Gas High (>145 PSI)

Reduce pressure from gas supply; defective pressure sensor (PS1).

3-4

Shield H2O High (>145 PSI)

Reduce pressure from gas supply; defective pressure sensor (PS2).

Group 4 - Proportional Valves & Solenoids Electrical Faults

4-1

Plasma High (V5) shorted

Check for shorted wire harness; Replace valve

4-2

Plasma Low (V4) shorted

Check for shorted wire harness; Replace valve

4-3

Pilot (V3) shorted

Check for shorted wire harness; Replace valve

4-4

Shield Gas (V1) shorted

Check for shorted wire harness; Replace valve

4-5

Shield H2O (V2) shorted

Check for shorted wire harness; Replace valve

4-6

Vent (SOL2) shorted

Check for shorted wire harness; Replace valve

4-7

Cut (SOL3) shorted

Check for shorted wire harness; Replace valve

4-8

Mark (SOL1) shorted

Check for shorted wire harness; Replace valve

4-9

Vent (SOL2) open

Check for open connection; Replace valve.

4-10 Cut (SOL3) open

Check for open connection; Replace valve.

4-11 Mark (SOL1) open

Check for open connection; Replace valve.

Group 5 - Plasma High Proportional Valve (V5)

5-1

Valve open

Check for open connection; Replace valve.

5-2

DPC inlet Supply pressure low Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply / hoses.

5-3

Outlet pressure too low

Valve full open. Leak in plasma hose to torch; defective control valve (V5); defective pressure

sensor (PS6); DPC Control PCB

5-4

Outlet pressure low

Tracking error Leak in plasma hose to torch; defective control valve (V5); defective pressure sen-

sor (PS6); DPC Control PCB

5-5

Outlet pressure too high.

Valve at minimun setting. Restriction in plasma hose, torch, DPC manifold; defective control

valve (V5); defective pressure sensor (PS6); DPC Control PCB

DPC Status Code Key

Code

Message

Cause/Remedy

Group 6 - Plasma Low Proportional Valve (V4)

6-1

Valve open

Check for open connection; Replace valve.

6-2

DPC inlet Supply pressure

low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.

6-3

Outlet pressure too low

Valve full open but pressure still too low. Leak in plasma hose to torch; Defective control valve (V4);

Defective pressure sensor (PS6); DPC Control PCB

6-4

Outlet pressure low

Tracking error. Leak in plasma hose to torch; Defective control valve (V4); Defective pressure sensor

(PS6); DPC Control PCB

6-5

Outlet pressure Too high

Valve at minimum setting but pressure still too high. Restriction in plasma hose to torch; torch or

DPC manifold; Defective control valve (V4); Defective pressure sensor (PS6); DPC Control PCB

6-6

Outlet pressure high

Tracking error. Restriction in plasma hose; torch or DPC manifold; Defective control valve (V4);

Defective pressure sensor (PS6); DPC Control PCB

Group 7 - Pilot Proportional Valve (V3)

7-1

Valve open

Check for open connection; Replace valve.

7-2

DPC inlet Supply pressure

low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.

7-3

Outlet pressure too low

Valve full open but pressure still too low. Leak in plasma hose to torch; defective control valve;

defective pressure sensor (PS6); DPC Control PCB

7-4

Outlet pressure low

Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure sensor

(PS6); DPC Control PCB

7-5

Outlet pressure Too high

Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch, DPC mani-

fold; defective control valve; defective pressure sensor (PS6); DPC Control PCB