Tweco 400 Ultra-Cut(May 2014) User Manual
Page 60
ULTRA-CUT 100 XT/200 XT/300 XT/400 XT
3-36
INSTALLATION Manual 0-5302
38.10mm
1.50in
190.50mm
7.50in
50.80mm
2.00in
203.20mm
8.00in
50.80mm
2.00in
38.10mm
1.50in
Art # A-12058
Installation
The Remote Arc Starter must be installed in a suitable location near the torch head.
If the Arc Starter is mounted to a gantry or
to any other support subject to motion or vibration, fasten the Arc Starter to the support securely.
1. Loosen, but do not remove, the lower screws securing the cover to the Arc Starter. Remove the upper screws securing
the Cover Panel to the Arc Starter.
NOTE
A ground wire connects the cover to the Arc Starter base. This wire must remain in place.
2. Remove the Cover Panel from the Arc Starter.
Art # A-12059
Lower screws
(2 per side)
Upper screws (2 per side)
Cover
Ground Wire
Cover Removal