Internal CNC connections. TB1, TB2 & TB3 on CCM module.

Connections are provided on the CCM module TB1, TB2 & TB3 terminal blocks including most of the rear panel functions plus

some additional features. All these signals are isolated from the plasma power supply but signals marked (comm.) and (-) are

common to each other.

Users are expected to install their own CNC cable to these connections. Knockout hole is provided in rear panel of CCM module.

User shall provide strain relief / cord grip for user installed cable.

TB1

Function

Connection

CNC Enable/Disable

TB1-2 (+), TB1-1(-)(comm.)

OK to Move 2

TB1-3 &TB1-12 Contacts only, rated 1A @ 28 VAC/DC

Stop Latched (NC)

4

TB1-4 (+) & TB1-5 (-) (comm.) used with Start Latched

Start/Stop Ret

4

TB1-6 (+), TB1-5 (-) (comm.)

or Start Latched (NO)

4

TB1-6 (+), TB1-5 (-) (comm.) used with Stop Latched

Divided Arc Voltage

TB1-8 (+), TB1-7 (-) comm.

Remote Analog Current Control

TB1-9 Analog Comm. (-) or 10K CC Pot low

TB1-10 Analog in (+) or CC Pot Wiper

TB1-11 10K CC Pot Hi (+10V @ 1 ma. Supply)

TB2

Function

Connection

Hold Start

TB2-2 (+),TB2-1 (-) (comm. )

Preflow ON

TB2-4 (+), TB2-3 (-) (comm.)

Pilot is ON (contacts)

TB2-6, TB2-8 rated 1A @ 120 VAC or 28 VDC

OK to Move (contacts or DC Volts)

TB2-12 (+), TB2-10 (-)

TB3

Function

Connection

Plasma Marking

TB3-2(+), TB3-1(-) (comm.)

Corner Current Reduction

TB-4(+), TB3-3(-)(comm.)

Cut Expanded Metal

TB3-6(+), TB3-5(-)(comm.)

Spare NO Contact

TB3-7, TB3-8

Spare NC Contact

TB3-9, TB3-10

Spare NO Contact

TB3-11, TB3-12