ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

Manual 0-5302

INSTALLATION

3-31

3.20 Fiber Optic Cable Installation from CCM to DMC-3000

CAUTION

Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into tight-radius

turns. Review section 3.10 for proper handling and installation of fiber optic cable.

1.

Remove outer thin nut from through hole protector at the end of Fiber Optic Cable (L) that is connected to the CCM.

2. Ensure that the cable is exposed beyond the through hole protector approximately 1” (as shown below) and secure by

tightening the wide nut with the rounded end while holding the other nut in place. Normal hand tightening is not enough.

3. Feed the Fiber Optic Cable plug and wires through the hole where shown then slide the thin nut back over the Fiber Optic

Cable.

Art # A-09148_AB

4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside and out.

Art # A-09149_AB