ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-46

INSTALLATION Manual 0-5302

Install the V-D Board.

1. Locate the V-D Board which should be with the iCNC.

2. Inside the Power Supply, locate and remove the mounting panel’s 2 screws and panel.

3. Install the V-D board standoffs and the V-D Board from the XT iCNC then reattach the panel with the 2 screws, securing

the V-D board in place. If using another V-D Board, follow the instructions provided mounting it in this same location.

Space for V-D Board

Ohmic clip cable port

V-D Board connection

V-D Board installed

Art # A-12079

V-D Board shown with optional wire harness for iHC controller

Control Cable.

The iHC board can be supplied with a wire harness and connector (shown in previous image), to be installed in the rear panel hole

labeled “Height Control” . The connector mates with a cable from the iHC. For other height control V-D boards a strain relief can

be installed in this hole for those cables. Refer to Appendix for wiring diagram.

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

Ohmic clip cable port

V-D Board connection

Art # A-12080

Arc Voltage Connections.

The XT plasma supplies provide a terminal strip, TB4, on the right side ahead of the CCM module for connections to Arc V- (Torch);

Tip V (Pilot); Arc V + (Work). If the V-D board requires separate power, 24 VAC and 120 VAC is available on the terminal strip

TB4. Refer to the wiring diagram in the Appendix for more information.