ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-18

INSTALLATION Manual 0-5302

CAUTION

Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into tight-radius

turns.

2. Remove outer thin nut from through hole protector at one end of Fiber Optic Cable (L) that connects between the CCM

portion of the Power Supply and the DMC-3000.

3. Feed the Fiber Optic Cable plug and wires through the hole where the plastic plug was removed labeled GCM/DMC and

slide the thin nut back over the Fiber Optic Cable.

4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside and out.

5. Plug the Fiber Optic Cable into the PCB as shown below. Make sure the locking tabs are engaged. Fiber Optic for the

DMC-3000 goes into the lower pair of fiber optic receptacles (U31 & U37).

Art # A-11998

Fiber Optic

Cable

Plug

Thin nut securing

the through hole

protector