Tweco 400 Ultra-Cut(May 2014) User Manual

Page 26

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-2

INSTALLATION Manual 0-5302

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Victor Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).

Coolant Capabilities

Cat. Number and Mixture

Mixture

Protects To

7-3580 ‘Extra-Cool™’

25 / 75

10° F / -12° C

7-3581 ‘Ultra-Cool™’

50 / 50

-27° F / -33° C

7-3582 ‘Extreme Cool™’

Concentrate*

-76° F / -60° C

* For mixing with D-I Cool™ 7-3583

3.02 System Layout 100 - 200 Amp

Refer to section 3.08 and 3.10 for ground connections and ground cables.

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-11995

Torch

Coolant Supply

Coolant Return

Control Cable

Pilot Return

Coolant Supply

Coolant Return

Plasma Gas

Shield Gas

Work Cable

DMC-3000

Gas

Console

Ultra-Cut

Power
Supply

DPC-3000

Gas

Control

Positioning Tube

Plasma Gas

Marking

Shield

Shield Gas

Negative

Pilot Return

Control Cable

100’ / 30.5 m Maximum Length

Shield

H

Q

R

U

S

A

B

C

D

E

P

K

L

O

I

J

G

175’ / 53.3 m Maximum Length

Preflow

Fiber Optic

L

Water Shield

T

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Fiber Optic

Control Cable

F

Touch

Screen

Controller

V

W

F1

F1

F

F

Ground Cable

to PS Only
When DMC
Mounted On
Top Of PS
-If not - Earth-

Advertising