ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-14

INSTALLATION Manual 0-5302

Avoid the following:

1. If you need to pull the cable through a power track do not fold the fiber back on itself making a sharp bend where it exits

the hose.

Art # A-09417

2. Do not hook onto the fiber to pull on the cable.

Art # A-09418

3. Once the fiber cable is installed in the CCM or gas control make sure the strain relief nut is securely tightened onto the

hose so the hose can’t pull out of it like this:

Art # A-09677_AB

Hose not secured in

the Strain Relief

Correct installation:

Correct way to pull the cable is to use a snake or a wire or another cable and attach it securely to the hose behind the strain relief.

Then secure the fiber connector to the pulling device leaving some slack in the fiber. Keep the protective end covers on the fiber

until you are ready to connect it to the PCB in the CCM or gas control.