ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

A-8

APPENDIX

Manual 0-5302

APPENDIX 7: CNC

CNC functions

CNC I/O circuits provide at least 1000V galvanic isolation from the plasma power supply.

While the CNC circuits are isolated from the power supply, many of the signal returns on J15 and TB1, TB2 & TB3 are common

to each other. J15 pins 1, 4, 5, 10, 17, and TB1-1, 5, 7, 9, and TB2-1 & 3 are all common. J15 pin 12 and TB2-10 are also con-

nected to the others when SW6 (OK to Move select) is set for voltage.

Rear Panel CNC Connector J15:

37 Circuit (Amp CPC) Remote Standard:

These are also duplicated on TB1, TB2 & TB3 use one or the other not both.

Chassis gnd (for SC-11 cable shield)

1

Start/Stop

3 (+); 4 (-)

Ok to Move (contacts or voltage 1)

12(-); 14 (+)

Divided Arc volts (selectable ratio

50:1; 40:1; 30:1; 16.6:1, 25:1)

5 (-); 6 (+)

PreFlow ON

7 (+); 9 (-)

Corner Current Reduction

10 (+); 11 (-)

Isolated Circuit Comm (for SC-11)

8

Chassis

Gnd

13

Keying

plug

15

Hold Start

16(+); 17 (-)

Plasma Mark

21 (+); 22 (-)

Cut Expanded Metal

23 (+); 24 (-)

CNC Plasma Enable2

25 (+); 26 (-)

Remote Analog Current Control 3

29 (+); 30 (signal); 31 (-)

Stop (Latched) SW4

32 (+); 33 (-)(comm.)

Pilot is ON (contacts)

34; 35

Spare (contact)

36; 37

1 SW6 on CCM I/O PCB selects OK to Move for isolated contact closure or DC Volts (15-18V) at <100ma. When set for con-

tacts, OK to Move circuit is rated for 120 VAC / 28 VDC

2Remove factory installed jumper from TB1-1 & 2 if using CNC Plasma Enable in J15.