Troubleshooting, General applicator troubleshooting – Great Plains NP3000A Operator Manual User Manual

Page 101

Advertising
background image

2014-04-22

Table of Contents

Index

407-613M

Great Plains Manufacturing, Inc.

Table of Contents

Index

97

Troubleshooting

General Applicator Troubleshooting.............................97
NH3 Metering System Troubleshooting .......................98
General Application Troubleshooting .........................100
Ground Drive Pump Troubleshooting.........................102
Hydraulic Drive Pump Troubleshooting......................103

The topics in this section presume that the applicator has
a Raven SCS 450 console, Raven AccuFlow™ metering
system, and CDS-John Blue

®

Impellicone

®

flow divider.

If also equipped with conventional liquid capability, the
topics in this section presume that the applicator is
equipped with a CDS-John Blue

®

pump and ground

drive, or a hydraulic pump and Raven SCS 450 console.

Troubleshooting sections are also found in the following
component manuals:

016-0159-403
Raven AccuFlow™ Operator manual

016-0159-831
Raven SCS-450 Installation, Operation and Service
manual

12-M-43
CDS-John Blue NGP Pump Parts and Instructional
manual

General Applicator Troubleshooting

Problem

Cause

Solution

Fold or unfold jerky or
imbalanced

Air in lines

Bleed fold/lift circuit (page 123).

Lift jerky or imbalanced

Air in lines

Bleed fold/lift circuit (page 122).

Lift-Assist casters
oscillating

Caster stabilizer too lightly set

Increase spring tension on caster
stabilizer piston (page 130).

Uneven application
depth

Excessive field speed.

Reduce field speed.

Coulters set too deep, lifting entire applicator

Reduce coulter depth.

Rough application conditions

Rework the field.

Worn tines inadequately preparing trench

Replace worn tines.

Wings too Shallow

Insufficient weight transferred to wings

Increase weight transfer (page 85).

Center too Shallow

Excess weight transferred to wings

Decrease weight transfer (page 85).

Sealers not compacting
the soil as desired.

Sealer adjustment not optimal.

Adjust sealer (page 80).

Not level front to rear.

Check applicator front-to-back level
(page 43).

Too wet or cloddy

Wait until drier weather or rework
ground.

2-Point Lift-Assist slow

Adjustment valve not fully open.

Open valve (page 161).

Advertising
This manual is related to the following products: