Nh3: making nurse tank connections, 2a12 – Great Plains NP3000A Operator Manual User Manual

Page 62

Advertising
background image

58

NP3000 and NP3000A

Table of Contents

Index

Great Plains Manufacturing, Inc.

407-613M

Table of Contents

Index

2014-04-22

NH

3

: Making Nurse Tank Connections

These instructions presume an applicator with Great
Plains-supplied Squib-Taylor Flo-Max™ coupler and
Raven AccuFlow™ application system.

1.

Perform the steps at “NH3: Safing Applicator
Before Cart Hitch
”, pages 55.

Anhydrous Ammonia Exposure Hazard:
Do not skip step 1. Wear your PPE

a

. Never open a line without

first performing a bleed to check it. If the applicator was
improperly shut-down, the hose can contain more NH

3

than

your PPE can handle. Lung damage, burning, blindness and
death are possible.

Refer to Figure 31
2.

Check that the two halves of the breakaway
coupler

are firmly mated at the swivel bracket.

If not, see the Squibb-Taylor Flo-Max™ manual for
re-connection instructions.

3.

Check that the break-away coupler bracket

is

free to swivel, relative to pointing directly rearward
horizontal, by at least:
80

° to each side,

45

° up, and;

20

° down.

4.

Remove, the Acme cap

on the inlet side of the

break-away coupler.

Refer to Figure 32
5.

Inspect the inlet Acme threads

. Clean away any

debris or other contamination.

Blinding, Choking and Respiratory Hazard:
Never look directly into an ammonia hose or fitting.
Use a mirror. Always assume that ammonia is present in the
system. There are many ways it can hide, and surprise you
later. See “Avoid Trapped Anhydrous” on page 106.

6.

Using a hand mirror, inspect the gasket

inside the

fitting

. If there is no sign of ammonia, and no

odor, you can remove the gasket by hand for closer
inspection.

This gasket makes the liquid-tight seal between the
hose and break-away coupler. Inspect it for a smooth
face, no cracks, chips or weathering, and no sign of
permanent compression. Replace gasket as needed
for a tight seal.

a. PPE: Personal Protective Equipment

Figure 31

Applicator NH

3

Inlet

31529

7

A18

A11

A14

A14

7

A11

Figure 32

Inspecting Fitting With Mirror

31565

2

A12

A12

2

A12

Advertising
This manual is related to the following products: