Liquid Operations

Operations for anhydrous nitrogen fertilizer begin on
page 55.

Liq: Filling On-Board Tanks

The tanks may be loaded from the quick-fill inlet, or from
the lids (page 69).

If the fertilizer solution has any tendency to settle,
sediment, gel, coagulate, precipitate or stratify, load
material immediately prior to application. The tank
system has no agitators for sustaining suspensions.

Apply fertilizer soon after material loading. Clean out
unused materials promptly. Fertilizer allowed to remain in
the tanks for an extended period can settle, resulting in
excessive or insufficient concentrations during
application. System plugging can also occur.

1.

Hitch the applicator to a tractor. Filling an unhitched
applicator is not recommended, as it can increase
parking stand loads above the bearing capacity of
the soil.

2.

Inspect the tanks from the lids.

3.

Drain excess condensation from the tank, so that this
water does not dilute the material to be loaded. See
Material Clean-Out (Liquid)” on page 118.

4.

Flush the tank if there is other residue present.

Liq: Tank Quick-Fill

Refer to Figure 39 and Figure 6 or Figure 5 on page 29 or 28
5.

Position the applicator on level ground, or tanks may
fill unevenly.

6.

Connect the nurse-tank hose to the quick-fill
coupler

located at the left end of the left tank.

Lock hose in place with cam-lock levers.

7.

Open the discharge valve (

, not shown) of each

tank to be filled. If filling must be performed on
unlevel ground, fill one tank at a time.

8.

Set the selector valve

to “FILL” (handle arrow

pointing forward, toward elbow from inlet).

9.

Open shut-off valve

at quick-fill coupler.

10. Open any supply valve and fill tanks. Tanks are

marked with fill levels.

11. Close valve at supply, then quick-fill coupler, and

disconnect the nurse tank hose.

12. Set selector valve to OFF, or to PUMP if applying

immediately.

L17

L15

L16

L18

Figure 39

Inlet and Selector Valve

32082

Agricultural Chemical Hazards:
Observe safety precautions specified by material suppliers.
Some chemicals can cause serious burns, lung damage and
death. Avoid contact with skin or eyes. Avoid prolonged
breathing of chemical fumes. Wear respirator and other
protective equipment as required by chemical manufacturer.
Seek medical assistance immediately if accident occurs. Know
what to do in case of an accident.

System Plugging Risk:
Use only pre-mixed liquid fertilizer. Fill tanks at field,
immediately prior to application. Do not use dry mixes. Do not
leave material in tanks for extended periods.

L16

L13

L15

L17