Plumbing diagrams, Nh3 plumbing diagrams, Nh3 system elements – Great Plains NP3000A Operator Manual User Manual

Page 150

Advertising
background image

146

NP3000 and NP3000A

Table of Contents

Index

Great Plains Manufacturing, Inc.

407-613M

Table of Contents

Index

2014-04-22

Plumbing Diagrams

Convention Liquid Diagrams begin on page 151.

NH

3

Plumbing Diagrams

See page 22 for a narrative.

NH

3

System Elements

The dual-cooler systems (page 149 and 150) differ from
the single-cooler systems (page 147 and 148) as follows:

• The inflow from the tank is split after the strainer

,

feeding two coolers

.

• Cooler outlets are merged prior to flow meter

.

• Refrigerant tap

is split.

• Two more tines

are dual-tube for vapor dispersal.

The section-control systems (pages 148 and 150) differ
from the single-section systems as follows:

• There is a check valve, bleed valve and 3-way flow

divider prior to section flow dividers.

• Each section flow divider has a shut-off solenoid valve.

A11. Acme cap

A31. Master Shut-Off Valve

A12. Acme inlet

A32. Refrigerant Tap

A13. Coupler Inlet Bleed Valve

A33. Refrigerant Line

A14. Breakaway Coupler

A34. Cooler Refrigerant Inlet

A15. Breakaway Hydrostatic Relief Valve

A35. Section Control Check Valve

A16. Coupler Outlet Bleed Valve

A36. Section Control Bleed Valve

A17. Supply Hose

A37. Section Control Relief Valve

A18. Emergency Shut-off Valve

A38. Section Flow Divider

A19. Strainer

A39. Section Shut-Off Valves

A20. Strainer Magnets

A40. Row Flow Divider(s)

A21. AccuFlow™ Super Cooler (Heat Exchanger)

A41. Flow Divider Manifold Inlet

A22. Cooler Intake

A42. Flow Divider Pressure Gauge

A23. Cooler Hydrostatic Relief Valve

A43. Flow Divider Outlet

A24. Cooler Outlet

A44. Flow Divider Plug

A25. Flow Meter

A45. Delivery Tube

A26. Drain Cap

A46. Coulter Tine (Single)

A27. Temperature Gauge

A47. Cooler Vapor Outlets (2)

A28. Pressure Gauge

A48. Vapor Tube

A29. Cooler Bleed Valve

A49. Coulter Tine (Dual)

A30. Control Valve

Legend:

For more details on components A11 through A49, see
NH3 System Narrative” on page 22.

Liquid NH

3

Liquid Flow

NH

3

Vapor

Vapor Flow

Direction of Flow

Exception Flow

A19

A24

A25

A32

A49

Advertising
This manual is related to the following products: