Nh3: check hydrostatic relief valves, Nh3: close bleed valves, Nh3: check hose discharged – Great Plains NP3000A Operator Manual User Manual

Page 60: Check hydrostatic relief valves, Close bleed valves, Check hose discharged

Advertising
background image

56

NP3000 and NP3000A

Table of Contents

Index

Great Plains Manufacturing, Inc.

407-613M

Table of Contents

Index

2014-04-22

NH

3

: Check Hydrostatic Relief Valves

3.

Check that the plastic cap is in place at each valve.
In the Great Plains configuration, this would be:

Ammonia Exposure and Loss Hazards:
Understand the reason for any lifted or missing hydrostatic
relief valve caps. If a cap is out of place, that line section may
have been closed with liquid NH

3

present, which later vented,

dislodging the cap. It is also possible that the valve disc has
deteriorated and is venting at normal operating pressures.

NH

3

: Close Bleed Valves

4.

Put on goggles and gloves. Approach the applicator
from up-wind.

5.

Check that all bleed valves are closed:

NH

3

: Check Hose Discharged

6.

Visually check the general condition of the
breakaway connection

. If the two halves appear

mated, use the inlet side bleed valve

for the next

step. Otherwise treat this as a breakaway event
(page 65).

7.

Orient the bleed valve orifice so that it points away
from you and down-wind.

8.

Wearing rubber chemical gloves, slowly open the
bleed valve

by rotating the T-handle

counter-clockwise.

Check for signs that there may be residual NH

3

in

between the Acme cap and the shut-off valve:
• strong ammonia odor
• hissing of escaping gas
• valve getting cold
• dripping or spraying fluid

9.

If there are any signs of residual NH

3

, leave the

bleed valve open until the ammonia has vented, and
the inlet fittings have re-warmed to ambient
temperature. This could take tens of minutes if the
applicator was recently and improperly shut down.

10. Close the bleed valve.

at each cooler

at the outlet side of the breakaway coupler

at the pressure/temperature gauges.

at the outlet side of the breakaway coupler.

at the inlet side of the breakaway coupler.

Figure 28

Hydrostatic Relief Valve

31564

A15

A23

A15

Figure 29

Applicator NH

3

Supply Hose

31529

Possible Chemical Hazard:
Wear your NH

3

PPE

a

. On a connection, residual NH

3

(possibly

in dangerous quantities) may be present in the applicator
systems, from the inlet Acme cap to the tines. NH

3

could also

be present in dangerous quantities between the Acme cap and
the cart shutoff valve. Unprotected exposure could result in
permanent lung/eye injury or death.

a. PPE: Personal Protective Equipment

A18

A14

A13

A29

A16

A13

A14

A13

A13

Advertising
This manual is related to the following products: