Appendix c - option setup, Hydraulic pump setup, Pump fittings and needle valve – Great Plains NP3000A Operator Manual User Manual

Page 166: Appendix c - option setup hydraulic pump setup

Advertising
background image

407-613M

Table of Contents

Index

2014-04-22

162

NP3000 and NP3000A

Table of Contents

Index

Great Plains Manufacturing, Inc.

Appendix C - Option Setup

Hydraulic Pump Setup

Pump Fittings and Needle Valve

Equipment Performance Risk:
Prior to first use, the pump fittings must be configured for the
type of hydraulic system provided by the tractor. If the system
is Open Center, the needle valve must also be adjusted.

As delivered, the hydraulic pump includes all fitting
necessary for use with any hydraulic system, but the
as-shipped pump configuration is suitable for use with no
system. Configure the pump before first use.

1.

Have the Ace Pump Instruction manual (HYD-MAN)
at hand for fitting use and adjustment details.

Refer to Figure 84 and table at right
2.

Determine the tractor hydraulic system type. Consult
the tractor operator manual.

3.

Remove one or both fittings ( or

), and as

necessary, adjust the needle valve

, based on the

system type.

Follow the instructions in the Ace manual.

For needle valve adjustment, obtain “dead head”
pressure by using the controller console to command the
flow control valve to closed (rate zero).

Figure 84

Pump Configuration

31965

Tractor Hydraulic

System Type

Pump Configuration

Required

Closed Center,

Load Sensing

(LS Closed)

Restrictor Orifice

OUT

Flow Limiter

IN

Needle Valve

closed

Closed Center,

Pressure Compensating

(PC Closed)

Restrictor Orifice

IN

Flow Limiter

OUT

Needle Valve

closed

Open Center

Restrictor Orifice

OUT

Flow Limiter

OUT

Needle Valve

adjusted

1

2

3

1

2

3

1

2

3

1

3

2

1

2

3

Advertising