Ground drive: set pump rate dial – Great Plains NP3000A Operator Manual User Manual
Page 99

Great Plains Manufacturing, Inc.
Fertilizer Rates
95
2014-04-22
407-613M
Ground Drive: Set Pump Rate Dial
Refer to Figure 64
Consult the 12-M-43 CDS-John Blue NGP Pump Parts
and Instructional manual for complete details on pump
operation and maintenance.
1.
Loosen the nut
at the setting pointer.
2.
Use the setting wrench
to rotate the dial until the
desired pump setting is under the pointer
.
Note: Settings below 2 are not recommended.
If presently using High range, switch to Low range
and use the dial setting for your rate in Low range.
3.
Tighten the nut.
Material Loss/Equipment Damage Risks:
Operate only with material loaded, or disconnect chain or
remove sprocket if not intending to apply material. Ground
drive wheel and chain system operate whenever the applicator
is lowered and in motion. The pump must not be run dry.
Figure 64
Adjuster for NGP-7055-K Pump
31320
8
7
9
7
8