Nh3: connect cart hose, Nh3: dry run, Dry run – Great Plains NP3000A Operator Manual User Manual

Page 63

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

59

2014-04-22

Table of Contents

Index

407-613M

NH

3

: Connect Cart Hose

Refer to Figure 33
Continue wearing your NH

3

PPE

a

.

7.

Verify that the nurse tank hose withdrawal valve
is closed. Hand tighten only. Do not use tools.

8.

Verify that any hose valves (

, not shown here)

are also closed. Hand tighten only. Do not use tools.

9.

Check for signs that there may be residual NH

3

in

between the Acme plug and the outlet shut-off valve:
• strong ammonia odor
• hissing of escaping gas
• fitting getting cold
• dripping or spraying fluid

If there are any signs of residual NH

3

, leave the plug

in, but loose, until the ammonia has vented, and the
Acme fitting has re-warmed to ambient temperature.
This could take tens of minutes if the cart was
improperly configured during or after filling.

10. Disconnect the outlet end of the hose

from the

Acme parking plug, or remove the Acme plug.
Inspect the outlet Acme threads. Clean away any
debris or other contamination.

Refer to Figure 33
11. Route the cart hose along the cart tongue, securing

it to any clamps or caddies provided.

Do not clamp or tie the hose within 3 feet (92 cm) of
the breakaway coupler inlet

.

Allow at least 13 inches (33 cm) slack in the hose
within the first 3 ft. Do not allow excess slack that
could allow the hose to snag or drag on the ground.

12. Bring the hose outlet

and applicator inlet

into contact. Hand tighten the swivel collar or shroud
on the hose fitting. Do not use tools. You only need
to adequately compress the gasket in the applicator
inlet.

NH

3

: Dry Run

Before activating the NH

3

delivery, cautious practice is to

make one dry run pass, including a turn in each
direction. This assures that tine depth is set correctly,
hydraulics are working correctly, the nurse tank cart is
tracking without issue, proper slack exists for all hoses
and harnesses, and the meter console is reporting
correct field speed.