Reverting to Pre-Emergence

For converting to pre-emergence, continue at page 164.

Resources required:

• s/n C1016-: Stands or blocks support the rear frame

• s/n C1016-: Hoist or lift for supporting casters during

shift

• all-purpose grease and grease gun

• basic hand tools

• One shut-off cap or plug.

Conventional liquid fertilizer:

832-042C NOZZLE SHUT OFF CAP W/ GASKET

Anhydrous:

830-407C PL 1/4 MNPT STAINLESS

Prepare Implement

13. Move implement to a level clear surface with

adequate illumination.

14. Raise implement.

15. Unfold wings.

16. Fully extend wing gauge wheels.

17. Install parking stands.

18. Place stands or blocks under the rear frame.

19. Retract the lift-assist cylinders to lift the caster tires

off the ground.

20. Lower implement onto stands.

21. Unhitch tractor.

22. Restore caster spacing.

23. Re-center 2-point hitch.

24. Note change in swath for rate setting.

Revert Liquid to Pre-Emergence

1.

Disconnect the drop line from the boom and the side
dress coulter. Cap the boom clamp.

2.

Disconnect the grease line at the grease bank.
Remove the zerk from the plate to prevent dirt
build up; re-attach zerk to line. Coil up the grease
line at the coulter.

3.

Dismount side dress coulter. If a quick-attach type,
leave the mount plate installed. Frame extension
may be left in place.

4.

Re-install rear coulters (if removed). Reconnect drop
and grease lines.

Revert NH

3

Side Dress to Pre-Emergence

Suffocation, Blinding, Burning, Freezing, Disabling and
Disfigurement Hazards:
Do not perform this installation reversion without PPE or
without verifying system discharge. This process requires
opening a flow divider port to the atmosphere. This system
segment could contain liquid anhydrous ammonia (NH

3

). It

would overwhelm your PPE

a

and could be fatal.

1.

Discharge system (see “System Discharge” on
page 108).

2.

Disconnect side dress delivery tubing at divider and
coulter. Leave tubing in place on frame.

3.

Replace adaptor at divider with plug.

4.

Dismount coulter. Frame extension may be left in
place.

Figure 107

Side Dress Removed

32029

L36

A44

a. PPE: Personal Protective Equipment