Row shutoff, Strainer adjustment, L36 l39 – Great Plains NP3000A Operator Manual User Manual

Page 97

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Fertilizer Rates

93

2014-04-22

Table of Contents

Index

407-613M

Row Shutoff

Refer to Figure 59
Unused drop lines may be shut off by replacing the
nozzle

with a Great Plains 832-051C cap

.

Nutri-Pro

®

boom systems typically have more nozzles

than coulters, and include caps for unused rows.

When installing a cap:

• It is not necessary to remove the gasketed orifice plate

from inside the clamp. The cap includes its own gasket
that seals at the end of the clamp port.

• Use a tie wrap or other line to secure the loose nozzle

and drop line tubing to the boom.

• Adjust pump and/or orifice plates for new rate and row

spacing.

Mis-Application or Material Loss Risk:
Do not apply materials after row shut-off or row turn-on
without first reviewing setup. Merely changing the number of
active rows does not change the application rate. If pump and/
or orifice size changes are not also made, pressures could be
too low or too high.

Strainer Adjustment

Refer to Figure 61
A Banjo brand strainer

is supplied with the ground

drive fertilizer pump. It is plumbed before the
CDS-John Blue pump. The standard 80 mesh screen
should be suitable for most applications. A 50 mesh
screen is available from Great Plains. Other screen sizes
are available from Banjo Corporation.

If changing screen sizes, keep in mind the following.

• A smaller mesh (100) keeps very small manifold

orifice plates from plugging so often. However, the
screen requires cleaning more often.

• If using variable rate nozzles, Spray Target

recommends use of a 50 mesh screen with the
VeriFlow nozzles available from Great Plains (part
number LST-1550).

• A larger mesh (50) or (30) passes more material but

should only be considered when using large manifold
orifice plates.

• Mesh sizes below 30 are not recommended for use

with CDS-John Blue pumps.

• A plugged or partially plugged screen starves the

pump resulting in a reduced application rate.

• Mesh sizes: (Smallest) 100, 80, 50, 30 (Largest)

L36

L39

Figure 60

Fertilizer Orifice Plate

29984

L39

L36

L18

Figure 61

Strainer

18418

1

L18

1