Pump maintenance and repair, Ace hydraulic pump, Coulter disc replacement – Great Plains NP3000A Operator Manual User Manual

Page 124: 22 inch coulters, 20 inch coulters

Advertising
background image

120

NP3000 and NP3000A

Table of Contents

Index

Great Plains Manufacturing, Inc.

407-613M

Table of Contents

Index

2014-04-22

Pump Maintenance and Repair

Ace Hydraulic Pump

The Ace pump is designed for long life and service.
Through the years, it may be necessary to replace the
mechanical seal or service components of the pump.
A mechanical seal may weep slightly, but if it starts to
drip, the pump will have to be disassembled. Before
disassembly, be sure to wash it out with fresh water.

If the pump leaks, before removal from applicator, run
the pump with adequate water in tank to diagnose the
actual pump problem.

Refer to the Ace Pump Instruction manual (HYD-MAN)
for disassembly instructions.

Coulter Disc Replacement

22 Inch Coulters

Replace 22 in. (56 cm) coulter blades when adjusting
application depth and/or applicator level becomes
difficult. Signs that blade replacement is indicated are:

• Coulter blade diameter is close to, or below,

20 in. (51 cm).

• Height adjustment, when level, requires no lift-assist

spacers (page 43).

• Tine height adjustment is at the upper limit (page 79).

See page 133 for replacement blades.

20 Inch Coulters

Replace 20 in. (51 cm) coulter blades when adjusting
application depth and/or applicator level becomes
difficult. Signs that blade replacement is indicated are:

• Coulter blade diameter is close to, or below,

18 in. (46 cm).

• Height adjustment, when level, requires no lift-assist

spacers (page 43).

• Fertilizer arm adjustment is at the upper limit

(page 82).

See page 134 for replacement and alternate coulter
blades.

Figure 75

Ace Pump Parts

31965

Advertising
This manual is related to the following products: