4.3.3 Network Management Module Setup

The steps to set up of the SNMP Management Module (NMS) are as follows:

Designate and set Time Slot jumpers on interface cards.

Set Configuration Switches (e.g., line buildout, line coding) on interface cards, as required.

Set Configuration Switches on Main Board (rear panel Master/Slave, Optics HI/LO Power), as required.

Set all system and I/O Port loopback switches to NOR.

If equipped with redundant optics, set the PRI/AUTO/SEC Switch to AUTO.

Set the DTE/DCE Switch on the SNMP Management Module to the required setting. If the device you are connecting
to the 3240S is a modem, this switch is set to DCE. If the device being connected to the 3240S is a PC or terminal, this
switch needs to be set to DTE. Plug in your EIA-232 cable, male/male straight-thru to the NMS Module.

Details for the setup of switch and jumper selections can be found in Chapter 2.

4-4