Values for SETUP MENU functions (defaults are BOLD):

SAMPLE RATE & FORMAT

DOLBY AC-2 48000 (STEREO)
48000 STEREO
48000 MONO
44100 STEREO
44100 MONO
32000 STEREO
32000 MONO

INPUT MONITOR

OFF, ON

THRESHOLD

-42 dB, OFF, -6 dB to –60 dB

OVERWRITE

OFF, ON

RECORDING TIME LIMIT

NONE, 30 SEC, 1 MIN, 5 MIN,
30 MIN, 60 MIN

RESTART MODE

ON COMPLETION,
IMMEDIATE

TIME DISPLAY

TIME REMAINING,
ELAPSED TIME

SORT DIRECTORY BY

INDEX, NAME

KEYBOARD TYPE

MINI, STANDARD

REMOTE CONTROL

INACTIVE,
ADDRESS (1-32)

CART SPINDOWN

ON, OFF

SYNC SOURCE

INTERNAL, DIGITAL INPUT

DIGITAL OUTPUT

PROFESSIONAL FORMAT,
CONSUMER FORMAT,
COPY PROTECTED
CONSUMER,
OFF

DIGITAL INPUT TYPE

AES/EBU XLR-3,
AES/SMPTE-75-OHM BNC,
IEC-958 TYPE II

AUDIO INPUT TYPE

ANALOG, DIGITAL

GENERAL PROCEDURE:

1. Press the SETUP MENU button.

2. Rotate the SELECT control to choose the option you wish to adjust.

3. Use POSITION buttons to select a new value for the option.

4. Press the ENTER button to confirm and exit or press the CANCEL, STOP or

PLAY buttons to exit.

You can adjust several options and then confirm or cancel all of them at once.

See Setup Menu Operations on page 29 for detailed procedures.