Operating Instructions

DigiCart/II Plus Owner's Manual

In addition to its function as an editing tool, Head Trim allows auditioning of any part of a file by
selecting the desired start time. Pressing CANCEL when done restores any programmed Head
Trim value or 00:00:00:00.

Press the EDIT MENU button and rotate the SELECT control to HEAD. The display will show
the current HEAD pointer for the cut:

HEAD 00:00:00:00

PRESS PLAY OR STOP

NOTE: DigiCart/II Plus has a minimum length of about two seconds for any cut. It is not possible
to use HEAD trim to further reduce this length. Since tight HEAD trims are usually more
important than TAIL trims, always perform the HEAD trim first, and then trim the TAIL if cut
length permits.

S

ETTING

T

HE

H

EAD

P

OINT

“O

N

T

HE

F

LY

Lets you listen to audio when setting a new HEAD pointer.

1. Press PLAY.

The cut will begin playing from 00:00:00:00.00.

2. Press STOP to set the new HEAD pointer. After pressing the STOP button, the

display will show the previous HEAD point on the top line and the newly selected
HEAD point on the bottom line.

HEAD 00:00:00:00

00:00:01:25:00 <F>

3. Use POSITION Arrows to set the scroll value in brackets as

<H> = Hours, <M> = Minutes, <S> = Seconds, <F> = Frames or <B> = Bits.

4. Use the SELECT control to fine-tune the HEAD point.

5. Press PLAY to audition the new HEAD point. Repeat steps 5 and 6 as needed.

6. Press ENTER to save the new HEAD pointer, or CANCEL to exit with no change.

S

ETTING

T

HE

H

EAD

P

OINT

W

HILE

S

TOPPED

To immediately begin editing the Head Trim without listening to audio:

1. Press STOP. The current HEAD point will be indicated on both top and bottom

lines.

HEAD 00:00:00:00

00:00:00:00:00 <F>

2. Use POSITION Arrows to set the scroll value in brackets as

<H> = Hours, <M> = Minutes, <S> = Seconds, <F> = Frames or <B> = Bits.

3. Use the SELECT control to fine-tune the HEAD point.

4. Press PLAY to audition the new HEAD point.

5. Repeat steps 3 and 4 as needed.