CHAPTER 7
Troubleshooting

1.

Determine why the Fast Fill Gate did
not close and correct the problem.

2.

Press the Clear button to clear the
alarm. The RESUME FILLING FAST
display appears. (See Fig. 7-7)

FIG. 7-7 RESUME FILLING FAST DISPLAY

3.

Press the Start button to resume fast
fill.

4.

If the target weight is NOT within the
target window and you do not have
the JOG function turned ON, the fill is
not accepted and an UNDER FILL! or
OVER FILL alarm appears depending
on the alarm condition.

Slow Gate Did Not Open Alarm

- - - - - ALARM CONDITION - - - - -

If the Slow Fill Gate is not open at the time
you want to slow fill, the SLOW GATE
DID NOT OPEN alarm appears on the dis-
play. (See Fig. 7-8)

FIG. 7-8 SLOW GATE DID NOT OPEN ALARM

1.

Determine why the Slow Fill Gate did
not open and correct the problem.

2.

Press the Clear button to clear the
alarm. The “RESUME FILLING
SLOW” display appears. (See Fig. 7-
9)

FIG. 7-9 RESUME FILLING SLOW

3.

Press the Start button to resume slow
filling.

Slow Gate Did Not Close Alarm

- - - - - ALARM CONDITION - - - - -

If the Slow Fill Gate does NOT close, the
SLOW GATE DID NOT CLOSE alarm
appears on the display. (See Fig. 7-10)

FIG. 7-10 SLOW GATE DID NOT CLOSE ALARM

1.

Determine why the slow Fill Gate did
not close and correct the problem.

2.

Press the Clear button to clear the
alarm. The Wait Timer display
appears. (See Fig. 7-11

FIG. 7-11 WAIT TIMER DISPLAY

3.

If the fill is within the target window
and you do not have the Discharge
Function turned ON (See Discharge
Function above), the instrument
returns to the Waiting On Display,
repeats the motion check, autozeros,
autotares and/or checks the OK to Fill
processes and begins fill cycle num-
ber 2, then 3, 4 and so on. (See Fig. 7-
11)