Step 4. If you are absolutely sure that this is what you want

to do press the Start button. The Output Relay dis-
play appears with the cursor in front of Output
Relay #1. (See Fig. 7-92)

FIG. 7-92 OUTPUT RELAY DISPLAY/SELECTING

OUTPUT RELAY #1

Step 5. To select another Output Relay, press the up or

down arrow buttons until the cursor is in front of
the Output Relay you want to force. (See Fig. 7-93)

FIG. 7-93 OUTPUT RELAY DISPLAY/SELECTING

OUTPUT RELAY #2

Step 6. Press the Enter button to activate the output relay

you have chosen. The Output Relay Forced Closed
display appears. (See Fig. 7-94)

All the output relays on the instrument are
Normally Open so activation will close the
relay.

FIG. 7-94 OUTPUT RELAY #1 FORCED CLOSED

DISPLAY

Step 7. Press the Exit button to return to the Output Relay

Display.

If you want to select another Output Relay
do so now.

If you do not want to select another Output
Relay, press the Exit button to return to the
Diagnostics display.

Step 8. Press the Exit button again to return to the Diagnos-

tics display.

State Logging

The State Logging function is user selectable and when on,
prints the various states the Filler/Dispenser goes through in
a fill. This will give you a written record of the states the
instrument went through during a Fill or Dispense. This is
useful information when troubleshooting the instrument and
your process.

Step 1. Press the up or down arrow buttons until the cursor

is in front of States Logging. (See Fig. 7-95)

FIG. 7-95 DIAGNOSTICS DISPLAY/SELECTION

STATE LOGGING - OFF

Step 2. Use the left or right arrow buttons to toggle

between ON and OFF. If you want to a written
record of the states during a fill or dispense toggle
the State Logging function ON. (See Fig. 7-96)

NOTE:

It is a good idea to turn off Auto print. If Auto
Print is turned ON you will get the fill informa-
tion plus the Logged States and it can get confus-
ing.

FIG. 7-96 DIAGNOSTICS DISPLAY/STATE LOG-

GING - ON

Step 3. Each time a state change occurs the State Logging

function will print out the Time in hours, minutes,
and seconds of the change state and the name of the
state.

Step 4. Press the Enter button to set the entry.

Advertising