Serial port parameters, About the serial port setup parameters, Refill menu/setting refill weight – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 52: Refill menu/setting refill timer, Setup menu/serial port, Serial port menu/printer port setup

HI-3010 Filler/Dispenser/IBC
36
Service Manual
FIG. 4-62 REFILL MENU/SETTING REFILL
WEIGHT
Step 15. Press the Clear button to clear the entry. Use the
Alphanumeric keypad to enter the new Refill
Weight.
Step 16. Press the Enter button to set the entry.
Step 17. Press the Down arrow to move the cursor in front of
Refill Timer. (See Fig. 4-63)
FIG. 4-63 REFILL MENU/SETTING REFILL TIMER
Step 18. Press the right or left arrow button to increase or
decrease the Refill time.
Step 19. Press the Enter button to set the entry.
Step 20. Press the Exit to return to the Main Menu.
Serial Port Parameters
About the Serial Port Setup Parameters
The Serial Port Parameters are set to operate the Printer
which can print out the status of a fill/dispense. The Printer
prints:
•
Date and time of the Fill/Dispense
•
Instrument ID
•
Ingredient ID
•
Each Amount Required
•
Number of Fills/Dispenses Requested
•
User ID
•
Time each fill began
•
Amount Requested per fill/dispense cycle
•
Actual amount received per fill/dispense
cycle
•
Alarms that occurred and times
•
Acceptance or Rejection of a fill/dispense
and time
•
Total Number of Cycles
•
Total Weight of the Fill/Dispense
The Printer provides a hard copy of a fill/dispense. You can
also select whether you want the Auto Print function which
will automatically print the results after every fill/dispense.
Check you Printer User Guide or Technical Manual to deter-
mine the parameters for your printer. If you don’t have the
Printer User guide or Technical Manual, check with your
Network Administrator for the parameter settings.
PARAMETER:BAUD RATE
RANGE: 300, 1200, 2400, 4800, 9600, 19200
DEFAULT: 9600
PARAMETER:PARITY
RANGE: NONE, ODD, EVEN
DEFAULT: NONE
PARAMETER:DATA BITS
RANGE: 7 OR 8
DEFAULT: 8
PARAMETER:AUTO PRINT
RANGE: ON/OF
DEFAULT: OFF
Step 1. Press the down arrow until the cursor is in front of
Serial Port. (See Fig. 4-64)
FIG. 4-64 SETUP MENU/SERIAL PORT
Step 2. Press the Enter button. The Serial Port Menu
appears with the cursor in front of Print Port. (See
Fig. 4-65)
FIG. 4-65 SERIAL PORT MENU/PRINTER PORT
SETUP
Step 3. Press the Enter button. The Printer Port Menu
appears. (See Fig. 4-66)
>
REFILL MENU
Ref il l Sw Timer 5s
Ref il l Wt 1000.00
Ref il l timer 60s
>
REFILL MENU
Ref il l Sw Timer 5s
Ref il l Wt 1000.00
Ref il l Timer 60s