HI-3010 Filler/Dispenser/IBC

68

Service Manual

Step 12. Click on “Fast Fill”. A Select button appears to the

right of the Control pull down menu. (See Fig. 6-8)

FIG. 6-7 CONTROL PULL DOWN MENU/

SELECTING FAST FILL

FIG. 6-8 SELECTING FAST FILL SOURCE

Step 13. Click on the Select button to select Fast Fill as the

Source. (See Fig. 6-8)

FIG. 6-9 MAPPING IS COMPLETE

Step 14. The Assignment Statement is complete. You will

now see in the Current Mappings text box:
HO0.0=HI2.1 (See Fig. 6-9)

Step 15. Click on the Map button. You have now mapped

Fast Fill to Output Relay #1. Notice that the new
mapping is included in the list of current mappings.
(See Fig. 6-10)

FIG. 6-10 MAPPED FAST FILL TO OUTPUT RELAY

#1

Example #2 Mapping to an Input

There are 5 contact closure inputs designed into the HI 3010.
You want to map Input Contact #4 to OK to Fill. Our Assign-
ment Statement is:

Destination = Source

Ok to Fill (HO1.4) = Input #4 (HI0.3)

Step 1. On the Configuration - Mapping Setup 1 page click

on the Control pull down menu. (See Fig. 6-11)

FIG. 6-11 DESTINATIONS/SELECTING OK TO FILL

Step 2. Click on Ok to Fill. A Select button appears. (See

Fig. 6-11)

Step 3. Click on the Select button. (See Fig. 6-11)

FIG. 6-12 OK TO FILL (HO1.4) SELECTED AS A

DESTINATION

Step 4. Click on the Jump to Sources Page button. The

Configuration - Mapping Setup 2 page appears.
(See Fig. 6-13)

Advertising