Configuration mapping setup 1/selecting a, Local output/selecting output relay #1 – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 82

Advertising
background image

HI-3010 Filler/Dispenser/IBC

66

Service Manual

FIG. 6-3 CONFIGURATION MAPPING SETUP 1/

SELECTING A DESTINATION

Step 3. Let’s take a moment to take a look at this page.

Local Outputs include the 4 Output
Relays.

Control includes parameters that control
the filling or dispensing which includes
the following which is only a partial list:

1.

OK to Fill,

2.

OK to Discharge

3.

Start

4.

Stop

Instrument Setup include parameters for
setting up the instrument itself and
includes the following which is only a par-
tial list:

1.

Auto Zero On

2.

Tare Value

3.

Zero Tolerance

4.

Discharge On

Ingredient Setup include parameters for
setting up the ingredients to fill or dis-
pense, and includes the following which is
only a partial list:

1.

Max Weight.

2.

Min Weight

3.

Fill Time

4.

Wait Time

Network includes the network outputs for
Hardy Control Link, ControlNet, Devi-
ceNet, Profibus etc. which is only a partial
list.

1.

Hardy Control-Link Text Out

2.

Hardy Control-Link Int Out

3.

DeviceNet Text Out

4.

DeviceNet Int Out

E-Mail includes E-Mail Outputs such as:

1.

Send E-Mail

2.

Custom Text

Calibration includes calibration parame-
ters:

1.

Zero Weight

2.

Span Weight

Scratchpad which are empty registers you
can do whatever you want with.

NOTE:

The lists above do not include all the parameters.
For a list of all the parameters and their
addresses please see Appendix A.

Step 4. Back to our example. We want to select Output

Relay #1 as our destination. Click on the Local Out-
puts pull down menu. (See Fig. 6-4)

Step 5. Click on Output Relay. After you click on Output

Relay it is selected and a Number and a Select but-
ton appear to the right of the Local Outputs pull
down menu. (See Fig. 6-4)

Step 6. To select Output Relays from 1 - 4, double click in

the text box and type in the Output Relay number
you want. In our example we selected Output Relay
#1. (See Fig. 6-4)

FIG. 6-4 LOCAL OUTPUT/SELECTING OUTPUT

RELAY #1

Step 7. Click on the Select button to the right of the Relay

#1 text box. An address appears in the Current
Mappings text box below. You will have to scroll