Devicenet parameters, About the devicenet parameters, Setup menu/devicenet – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 60: Devicenet menu/baud rate, Setup menu set cl ock - > devicenet - > et her net

Advertising
background image

HI-3010 Filler/Dispenser/IBC

44

Service Manual

Step 18. Check Table 4-2 for the time zone you are in.
Step 19. Press the right or left arrow until the correct time

zone appears. For example Pacific Standard Time is
-8.

Step 20. Press the Enter button to set the entry.
Step 21. Press the Exit button to return to the SETUP

MENU.

DeviceNet Parameters

About the DeviceNet Parameters

DeviceNet is a low-level network designed to connect the
Filler/Dispenser to higher-level controllers such as PCs,
PLCs or embedded controllers.The DeviceNet Network is an
open, global industry-standard communication network

designed to provide an interface through a single cable from
a programmable controller or PC directly to all HI 3000
Series products as well as smart devices such as sensors,
push buttons, motor starters, simple operator interfaces,
drives and other weight modules. With DeviceNet the user
can monitor or control multiple applications from one dis-
play and allows 3rd party I/O to be easily added to any sys-
tem. You no longer have to hard-wire each device to an I/O
module or I/O block. The network also provides access to
the intelligence present in the instruments for superior diag-
nostics and troubleshooting to help increase system up time.
The DeviceNet network lets you monitor your plant-floor
devices from a central location and reconfigure them as your
needs change or service them as required. You can, for
example, configure the Filler/Dispenser modules for differ-
ent applications.

PARAMETER:DEVICENET BAUD RATE
RANGE: 125K, 250K, 500K
DEFAULT: 125K

PARAMETER:DEVICENET NODE ADDRESS
RANGE: 0-64
DEFAULT: 0

Step 1. Press the Down arrow until the cursor is in front of

DeviceNet. (See Fig. 4-91)

FIG. 4-91 SETUP MENU/DEVICENET

Step 2. Press the Enter button. The DeviceNet Menu

appears with cursor in front of Baud Rate. (See Fig.
4-92)

FIG. 4-92 DEVICENET MENU/BAUD RATE

Step 3. Press the right or left arrow buttons to select the

Baud Rate you want.

+12

IDLE: International Date Line
East
NZST: New Zealand Standard

Wellington, NZ
Fiji
Marshall Islands

+13

Rawaki Island

+14

Line Islands

WEST OF GREENWICH

-1

WAT: West Africa

Azores
Cape Verde Islands

-2

AT: Azores

-3

Brasilia, Brazil
Buenos Aires, Argentina
Georgetown, Guyana

-3:30

Newfoundland

-4

AST: Atlantic Standard

Caracas, Venezuela
La Paz

-5

EST: Eastern Standard

Bogota, Colombia
Lima, Peru
New York, NY, USA

-6

CST: Central Standard

Chicago, Illinois, USA
Mexico City, Mexico
Saskatchewan, Canada

-7

MST: Mountain Standard

Phoenix, Arizona
Denver, Colorado

-8

Pacific Standard

Seattle, Washington
Portland, Oregon
San Francisco, CA

-9

YST: Yukon Standard

-10

AHST: Alaska-Hawaii Standard
CAT: Central Alaska
HST: Hawaii Standard

Anchorage, Alaska
Honolulu, Hawaii

-11

NT: Nome

Nome, Alaska

-12

IDLW: International Date Line
West

GMT

Civilian Time Zones

Cities

TABLE 4-2: GREENWICH TIME ZONES (GMT)

>

SETUP MENU
Set Cl ock - >
Devicenet - >
Et her net - >