Target window, About target window, Target preact parameter – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 42: Target preact sub-menu, Target preact menu/set preact, Rget preact menu/smart preact, Redient setup menu/selecting target

Advertising
background image

HI-3010 Filler/Dispenser/IBC

26

Service Manual

the Target Weight Tolerance. If it is not, the instrument auto-
matically calculates a new Target Preact so that the next
cycle is hitting the Target Weight. While the Smart Preact is
on, the Filler/Dispenser continues to determine the Smart
Preact Set Point maintaining and/or improving Fill/Dispense
accuracy.

PARAMETER:TARGET PREACT
RANGE: .000001 - 999,999
DEFAULT: 1.0 SMART PREACT: OFF

Step 1. The cursor is in front of Target Preact. (See Fig. 4-

18)

FIG. 4-18 TARGET PREACT PARAMETER

Step 2. Press the Enter button. The Target Preact Menu

appears. (See Fig. 4-19)

FIG. 4-19 TARGET PREACT SUB-MENU

Step 3. Press the Clear button to clear the previous entry.
Step 4. Use the alphanumeric key pad and enter the Target

Preact Value for this ingredient. In our example we
used 3.00 lbs as the Target Preact. (See Fig. 4-20)

FIG. 4-20 TARGET PREACT MENU/SET PREACT

Step 5. Press the down arrow button to move the cursor in

front of Smart Preact. (See Fig. 4-21)

Step 6. Use the left or right arrow to toggle between OFF

and ON. In our example we turned the Smart Preact
ON. (See Fig. 4-21)

FIG. 4-21 TARGET PREACT MENU/SMART

PREACT

Step 7. Press the Exit button to get back to the /Adjust

Ingredient 1 Menu.

Target Window

About Target Window

The Target Window is the weight tolerance for an ingredient.
There is a Maximum tolerance and a Minimum tolerance set-
ting. The Maximum tolerance is the weight above the target
weight you can accept you your process. The Minimum is
the weight below the target weight you can accept in your
process. The Target Window can be set as weight or percent-
age.

PARAMETER:TARGET WINDOW (WT)
RANGE: MIN WT. .000000-999,999

MAX WT. .000000-999,999

DEFAULT: 1.0

PARAMETER:TARGET WINDOW (%)
RANGE: MIN% 0.00-99.9

MAX% 0.00-99.9

DEFAULT: 2

Step 1. The cursor should be in front of Target Window. If

it is not, use the up and down arrow buttons to
move the cursor in front of Target Window. (See
Fig. 4-22)

Step 2. Press the left or right button to select Weight (WT)

or Percentage (%). (See Figs. 4-22 & 4-23)

FIG. 4-22 INGREDIENT SETUP MENU/SELECTING

TARGET WINDOW/WEIGHT

Advertising