Target window, About target window, Target preact parameter – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 42: Target preact sub-menu, Target preact menu/set preact, Rget preact menu/smart preact, Redient setup menu/selecting target

HI-3010 Filler/Dispenser/IBC
26
Service Manual
the Target Weight Tolerance. If it is not, the instrument auto-
matically calculates a new Target Preact so that the next
cycle is hitting the Target Weight. While the Smart Preact is
on, the Filler/Dispenser continues to determine the Smart
Preact Set Point maintaining and/or improving Fill/Dispense
accuracy.
PARAMETER:TARGET PREACT
RANGE: .000001 - 999,999
DEFAULT: 1.0 SMART PREACT: OFF
Step 1. The cursor is in front of Target Preact. (See Fig. 4-
18)
FIG. 4-18 TARGET PREACT PARAMETER
Step 2. Press the Enter button. The Target Preact Menu
appears. (See Fig. 4-19)
FIG. 4-19 TARGET PREACT SUB-MENU
Step 3. Press the Clear button to clear the previous entry.
Step 4. Use the alphanumeric key pad and enter the Target
Preact Value for this ingredient. In our example we
used 3.00 lbs as the Target Preact. (See Fig. 4-20)
FIG. 4-20 TARGET PREACT MENU/SET PREACT
Step 5. Press the down arrow button to move the cursor in
front of Smart Preact. (See Fig. 4-21)
Step 6. Use the left or right arrow to toggle between OFF
and ON. In our example we turned the Smart Preact
ON. (See Fig. 4-21)
FIG. 4-21 TARGET PREACT MENU/SMART
PREACT
Step 7. Press the Exit button to get back to the /Adjust
Ingredient 1 Menu.
Target Window
About Target Window
The Target Window is the weight tolerance for an ingredient.
There is a Maximum tolerance and a Minimum tolerance set-
ting. The Maximum tolerance is the weight above the target
weight you can accept you your process. The Minimum is
the weight below the target weight you can accept in your
process. The Target Window can be set as weight or percent-
age.
PARAMETER:TARGET WINDOW (WT)
RANGE: MIN WT. .000000-999,999
MAX WT. .000000-999,999
DEFAULT: 1.0
PARAMETER:TARGET WINDOW (%)
RANGE: MIN% 0.00-99.9
MAX% 0.00-99.9
DEFAULT: 2
Step 1. The cursor should be in front of Target Window. If
it is not, use the up and down arrow buttons to
move the cursor in front of Target Window. (See
Fig. 4-22)
Step 2. Press the left or right button to select Weight (WT)
or Percentage (%). (See Figs. 4-22 & 4-23)
FIG. 4-22 INGREDIENT SETUP MENU/SELECTING
TARGET WINDOW/WEIGHT