CHAPTER 6
Mapping

FIG. 6-42 HARDY CONTROL LINK NETWORK MAPPING

Boolean Mapping

A Boolean variable is a variable that can have the value 0
(FALSE) or 1 (TRUE). In the HI 3010 Filler/Dispenser there
are 3 boolean operations supported:

•

AND - The symbol for “AND” in a Bool-
ean Assignment Statement is “*”.

•

OR - The symbol for “OR” in a Boolean
Assignment Statement is “+”.

•

NOT - the symbol for “NOT” in a Boolean
Assignment Statement is “~”.

The Boolean image tables are arrays of short (2 byte) inte-
gers. An individual Boolean variable in the image table is
located by its word offset and its bit offset. Boolean image
tables are given 2 letter names as follows:

•

DI

is the DeviceNet input image table.

•

DO

is the DeviceNet output image

table.

•

HI

is the Hardy input image table.

•

HO

is the Hardy output image table.

•

RI

is RIO input image table.

•

RO

is RIO output image table.

The RIO input and output images tables are mapped to phys-
ical external devices using RSLogix. DeviceNet and Con-
trolNet input and output image tables are mapped to physical
external devices using Rockwell Software’s RS NetWorx.
The Hardy input and output image tables have pre-defined
meanings for certain bits within the tables.

NOTE:

Make sure you use RS NetWorx for DeviceNet
and RS NetWorx for ControlNet. They are two
different applications.

A Boolean variable is addressed with the syntax below:

[tablename][word offset].[bit offset]

Example:

DI0.3 is bit #3 in the DeviceNet input table, word #0.

Analog Mapping

An analog variable is one that can have many different val-
ues. The HI 3010 Filler/Dispenser supports float, 16 bit inte-
ger, and 32 bit integer analog variable types.

There are three (3) analog operations supported. The sym-
bols are the same as the Boolean operations, but with differ-
ent meanings.

•

Multiply - The symbol for “Multiply” is
“*”.

•

Add - The symbol for “Add” is “+”.

•

Negate - the symbol for “Negate” is “~”.

Analog tables are given 3 letter names as follows:

DFI, DFO, DSI, DSO, DII, DIO all refer to DeviceNet
tables, where the item is a float, a short integer, or a 32 bit
integer depending on the second letter in the table name. HFI
is a table of Hardy defined floating point numbers.

An analog variable is addressed with the syntax below:

[tablename][word offset]

The offset is an offset in words in the case of the DeviceNet
tables. The offsets in Hardy tables have various predefined
meanings.

•

HFI0 - is Gross Weight

•

HFI1 - is Net Weight

Mapping an Input to an Output Relay on Another HI 3010

HI 3010

Input Image

Table

Output Image

Table

Node #1

Input Contact #1

HI 3010

Input Image

Table

Output Image

Table

Node #2

0

1

2

3

Output

Hardy Boolean Out

Output Relay #3

From Sensor

0

1

2

3

4

Input

Hardy Boolean In

Too Actuator