137

Appendix A - HI 3010 Complete Mapping Symbols

HFO56 - Ingr.12 Min Wt
HFO57 - Ingr.1 Max % (Tolerance in %, above target wt)
HFO68 - Ingr.12 Max %
HFO69 - Ingr.1 Min % (Tolerance in %, below target wt)
HFO80 - Ingr.12 Min %
HFO81 - Ingr.1 Jog On Time (s)
HFO92 - Ingr.12 Jog On Time (s)
HFO93 - Ingr.1 Jog Off Time (s)
HFO104 - Ingr.12 Jog Off Time (s)
HFO105 - Ingr.1 Wait Time (s)
HFO116 - Ingr.12 Wait Time (s)
HFO117 - Ingr.1 Fast Target Wt (wt below target wt where
dual unit switches to slow feed)
HFO128 - Ingr.12 Fast Target Wt
HFO129 - Zero Tolerance (wt near zero that can be taken as
zero)
HFO130 - Auto Zero Tolerance (wt near zero that can be
zeroed)
HFO131 - Calibration Low Wt (wt used for "zero" of cali-
bration)
HFO132 - Calibration Span Wt (wt used for "span" of tradi-
tional calibration)
HFO133 - AutoZero Tolerance Time (time allowed for
autozeroing)
HFO134 - Tare Limit (max wt that can be tared off)

HTO - Hardy Text Output Table

HTO0 - Operator ID (max 3 chars)
HTO1 - Instrument ID (max 19 chars)
HTO2 - Custom Text0 (max 20 chars)
HTO3 - Custom Text1 (max 20 chars)
HTO11 - Custom Text9 (max 20 chars)
HTO12 - Ingredient 1 Name (max 19 chars)
HTO23 - Ingredient 12 Name (max 19 chars)
HTI - Hardy Text Input Table
HTI0 - Calibrator ID (max 3 chars)
HTI1 - Model Number (max 20 chars)
HTI2 - Program Part Number (max 20 chars)
HTI3 - Firmware Revision Number (max 20 chars)
HII - Hardy Integer Input Table
HII0 - Serial Number
HII1 - Totalizer0 Cycles
HII12 - Totalizer11 Cycles
HDI - Hardy Double Input Table
HDI0 - Totalizer0 Wt
HDI11 - Totalizer11 Wt

DI, DO, DFI, DFO, DSI, DSO, DII, DIO, DTI,
DTO - DeviceNet tables.

DeviceNet tables contain 125 16-bit words.

DI, DO = DeviceNet input/output, addressed as bits
DFI, DFO = DeviceNet input/output, addressed as floats

DSI, DSO = DeviceNet input/output, addressed as 16 bit
integers
DII, DIO = DeviceNet input/output, addressed as 32 bit inte-
gers
DTI, DTO = DeviceNet input/output, addressed as text

RI, RO, RFI, RFO, RSI, RSO, RII, RIO, RTI, RTO - RIO

(Allen-Bradley

®

Remote I/O tables). Used if you have an

RIO option card.
The RIO table is 64 words long, of which the first 32 are
mapped to and from the network.
The rest is used as a scratchpad area for short commands.

NOTE:

The block transfer area immediately follows dis-
crete area, and depends on rack size selected.

RI, RO = RIO input/output, addressed as bits
RFI, RFO = RIO input/output, addressed as floats
RSI, RSO = RIO input/output, addressed as 16 bit integers
RII, RIO = RIO input/output, addressed as 32 bit integers
RTI, RTO = RIO input/output, addressed as text

CI, CO, CFI, CFO, CSI, CSO, CII, CIO, CTI,
CTO - Communications Network tables.
Used if you have a Communications
option card.

The Communications Input table is 125 words long.
The Communications Output table is 127 words long, but
the first two words are reserved, if ControlNet.
otherwise, 125 words long.

CI, CO = Communications Network input/output,
addressed as bits
CFI, CFO = Communications Network input/output,
addressed as floats
CSI, CSO = Communications Network input/output,
addressed as 16 bit integers
CII, CIO = Communications Network input/output,
addressed as 32 bit integers
CTI, CTO = Communications Network input/output,
addressed as text