79

CHAPTER 6
Mapping

Command Interface

Parameter Numbers, Code Explanations and Valid
Ranges

CAUTION: T

HESE

VALUES

AND

EXPLANATIONS

CAN

CHANGE

. A

LWAYS

CHECK

ON

THE

H

ARDY

W

EB

S

ITE

FOR

THE

NEWEST

C

OMMAND

I

NTERFACE

L

IST

BEFORE

USING

THE

COMMAND

INTERFACE

.

NOTE:

Data is handled based on the method used writ-
ing data to the unit. If data is written using the
Command Interface (See Below) the data is inter-
preted based on the displayed units. However, if
data is directly mapped into the unit, the unit
assumes lbs (pounds) and converts the entered
data to the displayed units.

Parameter

Number

(Hexadecimal)

Code Explanation

Valid Range

0001

Operator ID

DFD

0002

Instrument ID

Max. 19 characters

0003

OK to Fill Timer

0-999

0004

WAVERSAVER

®

0 = None
5 = .25 Hz
4 = .50 Hz
3 = 1.0 Hz
2 = 3.50 Hz
1 = 7.50 Hz

0005

Number of Averages

1-250

0006

Zero Tolerance

0.000001-999999

0007

Units of Measure

0 = lb, 1 = Kg, 2 =
g 3 = oz

0008

Decimal Point

0-5

0009

Total Decimal Point

0-5

000A

Grad Size

0=1, 1=2, 2=5,
3=10, 4=20, 5=50,
6=100, 7=200,
8=500, 9=1000

000B

Print Total

1 = YES, 0 = NO

000C

Auto Print

1 = YES, 0 = NO

000D

Motion Tolerance

.01-999999

000E

Auto-Zero Tolerance

.000001-999999

000F

Capacity

.000001-999999

TABLE 6-2: PARAMETER NUMBER, CODE

EXPLANATION AND VALID RANGES

0010

Infrared Enable

1 = ON, 0 = OFF

0011

Active Target Weight

.000001-999999

0012

Active Num Cycles

0 = cont.,
or 1-999999

0013

OK to Fill Input

1 = YES, 0 = NO

0014

Discharge

1 = YES, 0 = NO

0015

Auto Discharge

1 = YES, 0 = NO

0016

OK to Discharge

1 = YES, 0 = NO

0017

Aux Device Time

0-999

0018

Discharge Gate
Proof

1 = YES, 0 = NO

0019

Discharge Gate
Timer (seconds)

0-99

001A

Use Auto-Zero

1 = YES, 0 = NO

001B

Auto-Zero Toler-
ance Time

.01-9.99

001C

Tare Limit

999999.0000

0022

Refill

1 = YES, 0 = NO

0023

Initial Refill

1 = YES, 0 = NO

0024

OK to Discharge
Timer (seconds)

0-999

002A

Baud Rate

0 = 300
1 = 1200
2 = 2400
3 = 4800
4 = 9600
5 = 19200

002B

Parity

0 = None
1 = Odd
2 = Even

002C

Data Bits

0 = 7 bits
1 = 8 bits

0038

Proof Switch

1 = YES, 0 = NO

0039

Gate Timer
(seconds)

0-99

003B

Refill Weight

.000001-999999

003C

Refill Duration Timer

0-999

003D

Auto-Tare time

5.0000

0200

Reference Weight

0.000001-999999
(Read Only)

Parameter

Number

(Hexadecimal)

Code Explanation

Valid Range

TABLE 6-2: PARAMETER NUMBER, CODE

EXPLANATION AND VALID RANGES

Advertising